PG 2A / 3A Maintenance
wc_tx000178gb.fm 27
5.3 Cleaning the Pump
See Graphic: wc_gr000837
After pumping water containing a large amount of dirt or debris, clean
out inside of pump housing.
5.3.1 Remove drain plug (b) from pump housing and drain any water left in
pump.
5.3.2 Loosen the four knobs holding the pump cover (a) and remove cover.
5.3.3 Clean out dirt and debris. Inspect impeller and volute insert for wear.
The impeller may develop sharp edges. Use care when cleaning
around impeller to avoid getting cut.
WARNING
w c _ g r 0 0 0 8 3 7
=
>